    LMC3-50 series RFID safety door switch

    1706678051308494.pngimage.png

    With detection confidentiality (unique code can be provided)

    ?Strong anti-interference, safety and reliability.

    ?Safety level PLe can be achieved by using safe dual-channel output technology.

    ?Effectively prevent false positives or false negatives, or artificial abnormal triggers.

    ?Can be used with the safety door.


    395181ccb7a771e30162f6415dc922a.png

    Ordering information

    86b9d0315b563dc534da6381bf695f3.png

    Switch model

    Specification

    Output method

    Encoding method

    LMC3-50-40SNT/5M


    4-core direct wiring with dual output
    5M cable


    NPN

    Universal encoding

    LMC3-50-40SN1/5M

    Unique encoding

    LMC3-50-40SPT/5M

    4-core direct wiring with dual output
    5M cable


    PNP

    Universal encoding

    LMC3-50-40SP1/5M

    Unique encoding

    LMC3-50-60JNT/5M

    6-core direct wiring with dual output and cascading 5M cable

    NPN

    Universal encoding

    LMC3-50-60JN1/5M

    Unique encoding

    LMC3-50-60JPT/5M

    6-core direct wiring with dual output and cascading 5M cable

    PNP

    Universal encoding

    LMC3-50-60JP1/5M

    Unique encoding

    395181ccb7a771e30162f6415dc922a.png

    Model Description


    395181ccb7a771e30162f6415dc922a.png

    Technical parameter

    Safty standard

    Mean Time to Dangerous Failure (MTTFd) (years)

    ISO13849-11EC/EN60947-5-1IEC/EN60947-5-3

    ≥30 years

    Safety classification

    Class 4 switch according to IS0 13849-1/suitable for PLe/PL

    Certification

    CE

    Horizontal working distance

    Conduction, min:10mm

    Vertical working distance

    Conduction, min:8mm

    Operating voltage

    24V DC±15%

    Operating current

    150mA

    Response time

    60ms

    The protection grades

    IP65, IP67 (customized)

    Operating frequency

    lHZ

    Working temperature

    -10~+55℃

    Relative humidity

    5%~95%

    Material

    Flame-retardant thermoplastic


    395181ccb7a771e30162f6415dc922a.png

    Shape and installation dimensions

    尺寸圖.pngLMC3-50.png


    395181ccb7a771e30162f6415dc922a.png

    Approach pattern of LMC3-50 switch

    1706679390304986.png1706679459242220.png


    395181ccb7a771e30162f6415dc922a.pngLMC3-50 switch induction distance


    Misalignment deviation

    breakover

    disconnect

    Alignment signal

    Horizontal alignment

    The deviation is within 4 mm in the X direction.Y direction induction 0~10mmY direction induction distance > 25mmLMC3-50.png
    The deviation is > 5mm and < -5mm in the x direction.Not recommended

    Vertical alignment

    The deviation is within 4mm of soil in X direction.Z direction induction distance 0~8mmZ direction induction distance > 23mmLMC3-510.png
    The deviation is > 5mm and < -5mm in the x direction.Not recommended


    395181ccb7a771e30162f6415dc922a.png

    Hookup

    Two-way output with cascade connection diagram

    serial number

    Signal definition

    colour

    explain

    1706680404188780.png

    1

    24V

    palm

    Power supply positive

    2

    0V

    blue

    Negative power supply

    3

    output1

    black

    Safety output 1

    4

    output2

    white

    Safety output 2

    5

    input1

    green

    Cascade input 1

    6

    input2

    yellow

    Cascade input 2


    395181ccb7a771e30162f6415dc922a.pngLegend of connection between RFID switch and safety relay module (dual output)


    接線圖.png



    395181ccb7a771e30162f6415dc922a.png

    RFID switch approach pattern

    Led display

    Signal state

    State description

    input

    output

    The red light is always on.

    Yes/No.

    break

    No actuator or incomplete alignment (universal coding)

    The red light is on for 1 second and then flashes twice (alternately).

    Yes/No.

    break

    No actuator or incomplete alignment (unique code)

    Red light flashing at 4Hz

    effective

    break

    Output overload

    Green light flashes at 1Hz.

    be invalid

    break

    No input signal (dual output is not applicable)

    The green light is always on

    effective

    through

    Induction is normal

    Alternate flashing of traffic lights

    effective

    break

    Label is not registered.


    Related Products
    Download
    PDF file download
    Video file download
    Previous

    Contact us

    400-881-6062

    Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

    E-Mail: info@lh-safety.com

    Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

    (Greenland East Coast International Plaza-Room A 313)

    Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

    Online service

    Online message

  • Click to refresh
  • 主站蜘蛛池模板: 人妻?无码?中出| 精品国产精品国产偷麻豆| 亚洲av免费在线观看| 合江县| 欧美日韩一区二区三区视频播放| 麻豆AV在线| 天堂av亚洲一区二区| 国产11一12周岁女毛片| 最近最新中文字幕免费的一页| 大黑人交xxxx18视频| 道孚县| 亚洲中文字幕无码av在线| 内射网址| 国产精品理论片在线观看| www.亚洲555久久久| 九九热在线视频观看精品| 国产一区二区日韩在线| 成人福利国产精品视频| 亚洲国产精品一区第二页| 成人精品视频一区二区三区尤物| 欧美最猛性xxxxx大叫| 嵩明县| 亚洲区小说区图片区qvod| 丁香久久婷婷| 国产aⅴ夜夜欢一区二区三区| 日韩一区二区三| 日韩深夜免费在线观看| 国产精品毛片一区视频播| 911亚洲国产自产| 精品国产乱码久久久久夜深人妻| 亚洲免费人成在线视频观看| 国产免费踩踏调教视频| 国产亚洲精品aaaaaaa片 | 天天摸天天做天天爽| 天天做天天爱夜夜爽导航| 农村乱人伦一区二区| 房山区| 久久国产欧美日韩精品图片| 吐鲁番市| 一边添奶一边添p好爽视频| 亚洲avav|