    Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
    Position首頁 > Home > Industrial Safety Products > Safety interlock switch > RFID Electromagnetic Locking Safety Door Switch
    D3SL-T/RFID electromagnetic locking type
    1.png

    ·Electromagnetic force locking 500N

    ·Adopt a small plane "electromagnetic" locking structure.

    ·Support 16 to 20 cascaded connections.

    ·Design of permanent magnet in matcher

    ·Small body, simple installation

    ·Full-angle eye-catching indicator light

    ·No abrasive powder will be produced.

    ·IP65/IP67 protection


    D3SL-T/RFID Series Selection Table

    Locking mode

    deploy

    model

    Output mode

    coded system

    Electromagnetic locking

    normalized form

    D3SL-T-DB-N2

    NPN

    universal coding

    D3SL-T-DB-N1

    NPN

    Unique coding

    D3SL-T-DB-P2

    PNP

    universal coding

    D3SL-T-DB-P1

    PNP

    Unique coding

    Advanced type

    D3SL-T-DG-N2

    NPN

    universal coding

    D3SL-T-DG-N1

    NPN

    Unique coding

    D3SL-T-DG-P2

    PNP

    universal coding

    D3SL-T-DG-P1

    PNP

    Unique coding


    Technical parameters of D3SL-T/RFID

    type

    Hinged door

    small-sized

    M12 connector

    normalized form

    High functional type

    working distance

    Sao(off-0n)

    4mm

    Sar(on-0ff)

    4mm

    Response time

    Lock → release

    155ms

    Release → lock

    155ms

    Detection → Non-detection

    20ms+2ms* (Number of cascaded connections -1)

    Non-detection → detection

    300ms+25ms* (Number of cascaded units -1)

    Control output

    (OSSD output)

    Output mode

    Transistor output "2

    Maximum load current

    150mA

    Residual voltage (on)

    Maximum ?2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

    OFF voltage

    Maximum ?2.0V (when the cable is 5m) and 3.0V (when the cable is 31m).

    leakage current

    Up to 0.5mA

    Maximum load capacity

    0.8uF

    Load connection resistance

    Max. 2.5 Euro

    AUX output

    (Non-safety system output)

    Output mode

    Transistor output

    Maximum load current

    50mA

    Residual voltage (ON)

    Maximum 2.5V (when the cable is 5m) and 3.5V (when the cable is 31m).

    external input

    (Short-circuit current)

    Safety input

    About 1.5 max 2

    Locking control input OSSD action switching input

    About 2.5 mA

    Reset /EDM input

    About 5mA (high functional type only)

    EDM select input

    About 2.5 mA (high functional type only)

    Power Supply 

    Power supply voltage

    24 VDC 10% including ripple (P-P)10% Class2

    consumed power

    <5W

    protective circuit

    Reverse connection protection of power supply, short circuit protection of outputs, surge protection of outputs and reverse connection protection of outputs.

    Environmental resistance

    Enclosure protection grade

    IP65/67(IEC60529)

    Operating ambient temperature

    20 degrees below zero to 55 degrees without freezing.

    Storage ambient temperature

    25 degrees below zero to 70 degrees without freezing.

    Using ambient humidity

    5% to 95%RH

    Storage environment humidity

    5% to 95%RH

    Vibration resistance

    10 to 55 Hz, double amplitude 2.0 mm, X, Y and Z directions for 5 minutes (IEC60947-5-3

    Applicable standards

    ENISO13849-1:2015(PLe,Category4), IEC60947-5-3,EN60947-5-3


    Model description of safety switch

     1728548977520914.png 



    hookup

    Standard type (NPN, cascade)

    Standard (PNP, cascade)

    1719978292858022.png

    Standard type (NPN, cascade)

    1719978426648983.png

    Standard (PNP, cascade)

    1719978725470017.png

    Functional (NPN, cascade)

    Functional (PNP, cascade)

    1719979076106539.png

    "Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

    "1. Use EDM and reset: wiring as shown in the figure.

    2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V.

    3. Only use EDM: Turn off the EDM selection (pink line).

    K1.K2: External equipment (forced guided relay, electric and magnetic contactor, etc.)

    S: reset switch

    "Open and close linkage, purple is connected with +24V; Locking linkage purple disconnection

    "1. Use EDM and reset: wiring as shown in the figure.

    2. Do not use EDM and reset: connect EDM selection (pink line) and reset /EDM (light color recording) to 0V.

    3. Only use EDM: Turn off the EDM selection (pink line).

    K1.K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

    S: reset switch

    High functional type (NPN, cascade)

    1719979521976024.png

    "Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

    1. Use EDM and reset: wiring as shown in the figure.

    2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V;

    3. Only use EDM: Turn off the EDM selection (pink line).

    K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

    S: reset switch

    "Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection

    1. Use EDM and reset: wiring as shown in the figure.

    2. Do not reset EDM: Select EDM (chalk line) and reset /EDM (light green) to+24V;

    3. EDM only: Turn off the EDM selection (chalk line).

    K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

    S: reset switch

    Functional (PNP, cascade)

    1719979875434469.png

    Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

    1. Use EDM and reset: wiring as shown in the figure.

    2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to OV;

    3. Only use EDM: Turn off the EDM selection (pink line).

    K1,K2: External equipment (forced-guided dimensional appliances, electromagnetic contactors, etc.)

    S: reset switch

    Open and close linkage, purple connected to +24V; Locking linkage purple disconnection

    *1. Make ?EDM and reset: wire as shown in the figure.

    2. Do not reset EDM: Select EDM (chalk line) and connect reset /EDM (light green) to 0V;

    3. EDM only: Turn off the EDM selection (chalk line).

    K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.)

    S: reset switch


    Indication of indicator light

    1719983442751425.png


    Product ruler diagram

    1719983681983392.png


    Selection Method of Safety Switch D3SL-T/RFID Series

    1728618489514684.png



    Related Products
    Download
    PDF file download
    Video file download
    Previous

    Contact us

    400-881-6062

    Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

    E-Mail: info@lh-safety.com

    Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

    (Greenland East Coast International Plaza-Room A 313)

    Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

    Online service

    Online message

  • Click to refresh
  • 主站蜘蛛池模板: 欧美牲交a欧美在线| 日韩欧美国产精品| 免费人成网上在线观看网址| 垣曲县| av无码av无码专区| 99精品久久久久久无码人妻| 欧洲亚洲无码| 国产一级片内射在线视频| 无码AV无码免费一区二区| 韩国三级a视频在线观看| 天等县| 风流老熟女一区二区三区| 东北露脸91| 亚洲综合伊人| 国产老熟女伦老熟妇露脸| 在线a人片免费观看| 久久精品亚洲精品国产色婷| 精品伊人久久久大香线蕉欧美| 国产成人午夜精华液| 娱乐| 日韩精品一区二区三区在线观看| 1024欧美日韩| 中文人妻无码一区二区三区在线| 日本亚洲国产| 亚洲精品成a人在线观看| 亚洲综合91社区精品福利| 色呦呦手机在线精品| 久久精品成人免费看| 男人一边吃奶一边做爰免费视频| 久久精品国产曰本波多野结衣| 国产成人久久精品二区三区| 先锋影音av最新资源| 泉州市| 久久天天躁狠狠躁夜夜av不卡| 啊片在线观看| 日本va欧美va精品发布| 丝袜shi在线播放| 亚洲中文字幕不卡| 亚洲性受| 国产成人小视频| 亚洲色成人网站www永久四虎|